Resolution 14 mm (finger protection), Protection field height up to 1200 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Slim design, mounting on three sides, Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m
, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 1200 mmfa
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 60 mm , Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 90 mm, Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 14 mm (finger protection), Protection field height up to 1200 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 1200 mmfa
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 60 mm , Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Resolution 90 mm, Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mmfa
Deflecting mirror for multi-sided protection safety layouts using SLC series safety light gridsfa