Serviceline Industriële Sensoren
Serviceline Explosiebeveiliging

Termination Board HiCTB32-TRI-DIISS-EL-PL

HiCTB32-TRI-DIISS-EL-PL
  • System board for Schneider Electric, Tricon series by Triconex
  • TAN48 approval
  • For 64-channel (32+32) DI card 3564
  • For 32 modules
  • Recommended module: HiC2821 (DI)
  • 24 V DC supply
  • Hazardous area: pluggable screw terminals, blue
  • Non-hazardous area: ELCO socket, 56-pin

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Technische gegevens  HiCTB32-TRI-DIISS-EL-PL

Supply
ConnectionX20: terminals 3, 5(+); 4, 6(-)
Nominal voltage24 V DC , in consideration of rated voltage of used isolators
Voltage drop0.9 V , voltage drop across the series diode on the termination board must be considered
Ripple≤ 10 %
Fusing4 A , in each case for 32 modules
Power dissipation≤ 500 mW , without modules
Reverse polarity protectionyes
Redundancy
SupplyRedundancy available. The supply for the isolators is decoupled, monitored and fused.
Fault indication output
Connectionfault bus (Fault) : X20: terminals 1, 2
Output typevolt-free contact
Switch behaviourfault bus (Fault)
- no fault: relay contact of the fault indication board closed
- power supply fault: relay contact of the fault indication board open
- module fault: relay contact of the fault indication board open
Contact loadingfault bus (Fault) : 30 V DC , 1 A , see fault indication board
Indicators/settings
Display elementsLED PWR1 (termination board power supply), green LED
LED PWR2 (termination board power supply), green LED
Configurationjumper SW1: card selection
- position 1: DI card 3564
- position 2: n.c. (factory setting)
- position 3: DI card 3504E
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2017
For further information see system description.
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Degree of protectionIP20
Connection
Field sideexplosion hazardous area: pluggable screw terminals , blue
Control sidenon-explosion hazardous area: ELCO socket, 56-pin
Supplypluggable screw terminals , black
Fault outputpluggable screw terminals , black
Core cross sectionscrew terminals: 0.2 ... 2.5 mm2 (24 ... 12 AWG)
Materialhousing: polycarbonate, 10 % glass fiber reinforced
Massapprox. 1470 g
Dimensions432 x 200 x 163 mm (17 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly
Height200 mm
Width432 mm
Depth163 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificateCESI 06 ATEX 022
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Non-hazardous area
Maximum safe voltage250 V (Attention! Um is no rated voltage.)
Galvanic isolation
Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000
International approvals
UL approvalE106378
Control drawing116-0327
IECEx approval
IECEx certificateIECEx CES 06.0003
IECEx marking[Ex ia Ga] IIC
[Ex ia Da] IIIC
[Ex ia Ma] I
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210121
ECLASS 12.027210121
ECLASS 11.027210121
ECLASS 10.0.127210121
ECLASS 9.027210121
ECLASS 8.027210121
ECLASS 5.127210121
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.139121008

Details: HiCTB32-TRI-DIISS-EL-PL

Datasheet: HiCTB32-TRI-DIISS-EL-PL

DatasheetBestandstypeBestandsgrootte
Datasheet HiCTB32-TRI-DIISS-EL-PLPDF1431 KB
Fiche de données HiCTB32-TRI-DIISS-EL-PLPDF1438 KB
Datenblatt HiCTB32-TRI-DIISS-EL-PLPDF1436 KB
Datasheet HiCTB32-TRI-DIISS-EL-PLPDF1496 KB
Hoja de datos HiCTB32-TRI-DIISS-EL-PLPDF1438 KB

Documents: HiCTB32-TRI-DIISS-EL-PL

ManualsBestandstypeBestandsgrootte
System ManualPDF5438 KB
SystemhandbuchPDF5450 KB
Instruction manuals
ИнструкцииPDF162 KB
Instruction manual / BetriebsanleitungPDF317 KB
Návod k poużitíPDF157 KB
Instruktions manualPDF156 KB
Instruction manualPDF161 KB
KasutusjuhendPDF153 KB
KäyttöohjePDF153 KB
Manuel d'instructionsPDF158 KB
BetriebsanleitungPDF162 KB
Οδηγίες χρήσηςPDF165 KB
HandleidingPDF157 KB
Instruction manual / BetriebsanleitungPDF156 KB
Használati útmutatóPDF157 KB
Manuale di istruzioniPDF156 KB
Lietošanas pamācībaPDF156 KB
Instrukciju vadovasPDF157 KB
Instrukcja obsługiPDF158 KB
Manual de instruçõesPDF157 KB
Manual de utilizarePDF157 KB
Návod na poużitiePDF156 KB
Navodila za uporaboPDF155 KB
Manual de instruccionesPDF157 KB
ManualPDF154 KB
Short instructions, safety information
Brief instructionsPDF3356 KB
KurzanleitungPDF3365 KB
Technical information
Pinout TablePDF112 KB

Aanverwante producten: HiCTB32-TRI-DIISS-EL-PL

Accessories

For HiC Termination Boards, 1 piece for 8-position Termination Board, 2 pieces for 16-position Termination Boardpa
1-channel, 24 V DC supply, Monitors up to 16 HiC Termination Boards, Relay contact output, LEDs for supply and fault statuspa
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 relay contact outputs, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contactpa