Inductive sensor NBB3-V3-E1-V3

NBB3-V3-E1-V3
  • 3 mm flush
  • 3-wire DC

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Technische gegevens  NBB3-V3-E1-V3

General specifications
Switching functionNormally closed (NC)
Output typeNPN
Rated operating distance3 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 2.43 mm
Reduction factor rAl 0.35
Reduction factor rCu 0.33
Reduction factor r304 0.82
Reduction factor rBrass 0.5
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 1000 Hz
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 3 V
Operating current0 ... 100 mA
Off-state current0 ... 0.5 mA typ. 0.1 µA at 25 °C
No-load supply current≤ 15 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd2300 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector plug M8 x 1 , 3-pin
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Tightening torque, fastening screws≤ 0.4 Nm
Dimensions
Height10.2 mm
Width27.8 mm
Length16 mm

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NBB3-V3-E1-V3

Datasheet: NBB3-V3-E1-V3

DatasheetBestandstypeBestandsgrootte
Datasheet NBB3-V3-E1-V3PDF627 KB
Datasheet NBB3-V3-E1-V3PDF625 KB
Fiche de données NBB3-V3-E1-V3PDF623 KB
Datenblatt NBB3-V3-E1-V3PDF627 KB
Scheda tecnica NBB3-V3-E1-V3PDF624 KB
Datasheet NBB3-V3-E1-V3PDF610 KB
Folha de dados NBB3-V3-E1-V3PDF605 KB
Hoja de datos NBB3-V3-E1-V3PDF605 KB
Datasheet NBB3-V3-E1-V3PDF619 KB

Documents: NBB3-V3-E1-V3

Technical informationBestandstypeBestandsgrootte
Installation conditionsPDF130 KB
EinbaubedingungenPDF132 KB

CAD+CAE: NBB3-V3-E1-V3

CADBestandstypeBestandsgrootte
CAD 3-D / CAD 3-DSTP87 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: NBB3-V3-E1-V3

CertificatesBestandstypeBestandsgrootte
China Information on CCCPDF457 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1218 KB
UK Declaration of Conformity (P+F)PDF1284 KB

Aanverwante producten: NBB3-V3-E1-V3

Accessories

Female cordset single-ended M8 angled A-coded, 3-pin, PUR cable greyfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont met Active Shielding Technology

De inductieve VariKont-sensoren met Active Shielding Technology bieden grote schakelafstanden, ongeacht de montageomstandigheden of omgevingsinvloeden. Haal voordeel uit vereenvoudigd installatieontwerp en beperkte kosten!

Inductive Safety Sensors SIL 2 PL d

Gezien de SIL 2-/PL d-geclassificeerde inductieve veiligheidssensoren geen dode zone hebben, kan de gegevensoverdracht worden gewaarborgd zonder handhaving van een minimumafstand tussen sensor en doel. Ontdek onze geoptimaliseerde portfolio voor zware industriële omgevingen.