Serviceline
Serviceline Industriële Sensoren
Serviceline Explosiebeveiliging

Solenoid Drivers


Verfijn zoek criteria

Resultaat product selectie:: 8 Product(en)

Function

Input

Power Supply

Output

Special


Selecteer uw product


Product

1-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 12 V DC, Up to SIL3 acc. to IEC 61508pa

2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 12 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 110 mA, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
1-channel isolated barrier, 24 V DC supply (bus powered), Analog input, digital input,
analog output, digital output, No configuration required, device is self-adapting, HART transparency, Low power dissipation, 3-way isolation, Up to SIL 2 acc. to IEC 61508 in preparationpa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 12 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 110 mA, Line fault detection (LFD), Test pulse immunity, Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL3 acc. to IEC 61508pa
2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 11.2 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 60 mA at 13 V DC, 65 mA current limit, Gas group IIB, Contact or logic control input, Line fault detection (LFD) with separate output, Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 11.2 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Test pulse immunity, Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL3 acc. to IEC 61508 (loop powered)pa
Download het compendium voor Functionele Veiligheid

Gratis downloadbestand: Compendium voor Functionele Veiligheid

Download ons gratis compendium voor Functionele Veiligheid in pdf-vorm en leer meer over de specifieke normen en methodes voor risicobeperking. We tonen je ook hoe je veiligheidsapparatuur in je systeem kan integreren en bieden je een handige woordenlijst om je te helpen bij je dagelijkse taken.