Serviceline Industriële Sensoren
Serviceline Explosiebeveiliging

Modules voor DIN-rail montage

Kies uw product

Volgende paginaLaatste pagina
Product

Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

Surge protection barrier for 2 signal lines, Nominal voltage 24 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

Surge protection barrier for 2 signal lines, Nominal voltage 24 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

Surge protection barrier for 2 signal lines, Nominal voltage 24 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

Surge protection barrier for 2 signal lines, Nominal voltage 24 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)pa

For surge protection system M-LB-2000, Color black, DIN rail mountablepa

Surge protection for 2 signal lines, Nominal voltage 5 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per linepa
Volgende paginaLaatste pagina

Filter Op

Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.

De “Functional Safety Hub” van Pepperl+Fuchs

Honderden producten met een SIL-/ PL-classificatie, gratis tools en brochures in één locatie: de "Functional Safety Hub" is uw startpunt voor al uw veiligheidsfuncties.