Conductive Switch Amplifier

View All Products in Group:
Conductive Switch Amplifier
![]() | ![]() | ![]() | ![]() | |||||||||||
| Product | Short Description |
|---|---|
| Conductivity Switch Amplifier KFA5-ER-Ex1.W.LB | 1-channel isolated barrier, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA5-ER-1.W.LB | 1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA5-ER-1.5 | 1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA5-ER-1.6 | 1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA5-ER-2.W.LB | 2-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA6-ER-Ex1.W.LB | 1-channel isolated barrier, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA6-ER-1.W.LB | 1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA6-ER-1.5 | 1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA6-ER-1.6 | 1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay |
| Conductivity Switch Amplifier KFA6-ER-2.W.LB | 2-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay |
![]() | ![]() | ![]() | ![]() | |||||||||||