[Land selecteren]   Nederland
You must have cookies enabled to get the best browsing experience on our website.
Learn how to enable cookies.



Switch Amplifiers





View All Products in Group: Switch Amplifiers


First PagePrevious Page1 - 10 ( of 20 ) Next PageLast Page
Items per Page:
ProductShort Description
Switch Amplifier
KCD2-SR-1.LB
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Switch Amplifier
KCD2-SR-1.LB.SP
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Switch Amplifier
KCD2-SR-2
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Switch Amplifier
KCD2-SR-2.SP
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Conductivity Switch Amplifier
KFA5-ER-1.W.LB
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-1.5
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-1.6
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-2.W.LB
2-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA6-ER-1.W.LB
1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA6-ER-1.5
1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay
First PagePrevious Page1 - 10 ( of 20 ) Next PageLast Page
Items per Page:

Informatie+Service

Telefoon +31 (0)73-750 71 07
Fax +31 (0)73-644 47 49